Vertical Multistage Pump
All
Vertical Multistage Pump
After-sale Service

Vertical Multistage Pump

1.What is difference between SDL and SDLT, are their performance same?

The SDL(F) Vertical multistage stainless steel pump is applicable to conveying non-corrosive liquid, while SDLF is suitable for Slightly corrosive liquid. The transported liquid can be various cold, hot, non flammable and explosive, and impurity free liquids.The inside impeller, diffuser, shaft, outer casing and other main components are all stainless steel punched. The pump body has the advantages of stamping pump, standard impeller, small flow and high head. This kind of pump can be equipped with an intelligent protector to effectively prevent it from dry-running, out-of-phase and overload.The pump boasts characters of high efficiency, low noise, steady operation, etc. The pump set adopts the non-self-priming vertical multi-stage structure, which makes a compact whole, its installation easy, its operation and maintenance convenient.

2. What is the biggest rated flow of SDL model

The biggest rated flow is 200m³/h of SDL200 series, the Max.flow can be 240m³/h

3.How many connection type for SDL series?

For SDL1-SDL20 there are four connection type: Victaulic, thread, oval flange, round flangeFor SDL32 and bigger, only round flange connectionNEMA standard flange also available.

4. SDL can be used for what temperature range?

We have two types:- Standard type:  -15℃~+70℃- Hot water type: -15℃~+105℃

5.What material for SDL series available?

Cast Iron, SS304, SS316, duplex 2205

6.What type mechanical seal and what is the standard material

It is a cartridge mechanicalMaterial is Graphite/Tungsten carbide, for O ring is Viton.